1.
Arq. bras. oftalmol ; 82(2): 129-135, Mar.-Apr. 2019. graf
Article in English | LILACS | ID: biblio-989398

ABSTRACT

ABSTRACT Purpose: To determine the reliability of swept- source optical coherence tomography in cases in which soft contact lenses cannot be removed when acquiring biometric measurements. Methods: Eight subjects were included and only one eye per participant was analyzed. Each eye was measured six times by swept-source optical coherence tomography with the IOLMaster 700 instrument (Carl Zeiss Meditec, Jena, Germany). Axial length, central corneal thickness, anterior chamber depth, lens thickness, and keratometric measurements were evaluated for the naked eye and while wearing soft contact lenses of three different powers (-1.5, -3.0, and +2.0 D). Results: There were statistically significant changes in axial length, central corneal thickness, anterior chamber depth, and keratometric measurements with soft contact lenses as compared to the naked eye (p<0.001). However, there were no significant differences in lens thickness outcomes between the naked eye and while wearing the three soft contact lenses (p>0.5). The changes in axial length, central corneal thickness, and anterior chamber depth were lens-specific and dependent on the thickness of the lens used. Conclusions: Sept-source optical coherence tomography based lens thickness measurements while wearing soft contact lenses are comparable to those of the naked eye. However, the thickness and the optical design of the soft contact lens may lead to significant differences in the axial lengh, central corneal thickness, anterior chamber deph, and keratometric measurements.


RESUMO Objetivo: Determinar a confiabilidade da tomografia de coerência óptica de varredura em casos especiais em que lentes de contato gelatinosas não podem ser removidas ao realizar medições biométricas. Métodos: Oito indivíduos foram incluídos e apenas um olho por participante foi analisado. Cada olho foi medido seis vezes por tomografia de coerência óptica de varredura com o instrumento IOLMaster 700 (Carl Zeiss Meditec, Jena, Alemanha). O comprimento axial, a espessura central da córnea, a profundidade da câmara anterior, a espessura da lente e as medidas ceratométricas foram avaliados a olho nu e enquanto usavam lentes de contato gelatinosas de três diferentes potências (-1,5, -3,0 e +2,0 D). Resultados: Houve alterações significativas no comprimento axial, espessura central da córnea, profundidade da câmara anterior e medidas ceratométricas com as lentes de contato gelatinosas em comparação com as a olho nu (p<0,001). No entanto, não houve diferenças significativas nos resultados de espessura do cristalino entre o olho nu e enquanto usava as três lentes de contato gelatinosas (p>0,5). As alterações de comprimento axial, espessura central da córnea e profundidade da câmara anterior foram específicas da lente e dependentes da espessura da lente usada. Conclusões: As medições da espessura da lente baseadas na tomografia de coerência óptica da Sept-source, enquanto usam lentes de lentes de contato gelatinosas, são comparáveis às do olho nu. Entretanto, a es pessura e o desenho óptico da lente de contato gelatinosa podem levar a diferenças significativas no comprimento axial, na espessura central da córnea, na profundidade da câmara anterior e nas medidas ceratométricas.


Subject(s)
Humans , Adult , Biometry/methods , Contact Lenses , Tomography, Optical Coherence/methods , Axial Length, Eye/anatomy & histology , Axial Length, Eye/diagnostic imaging , Anterior Eye Segment/anatomy & histology , Anterior Eye Segment/diagnostic imaging , Reference Values , Reproducibility of Results , Analysis of Variance , Statistics, Nonparametric , Cross-Over Studies
2.
Clinics ; 73: e491, 2018. tab, graf
Article in English | LILACS | ID: biblio-952791

ABSTRACT

OBJECTIVE: To evaluate the relationship of biomechanical properties, corneal hysteresis and corneal resistance factor with age, sex and various corneal parameters measured with a Pentacam in normal subjects. METHODS: A total of 226 eyes from 113 patients were enrolled in this study. The subjects underwent Ocular Response Analyzer and Pentacam evaluations. A varying-intercept multilevel regression was implemented using Bayesian inference. The predictor variables were age, sex, central corneal thickness, corneal volume at a 7-mm diameter, anterior chamber angle and volume, anterior chamber depth, mean radius of the corneal curvature and corneal astigmatism. RESULTS: Corneal hysteresis ranged from 5.5 to 14.8 mmHg (mean 10.42±1.74 mmHg), and the corneal resistance factor ranged from 5.7 to 15.5 mmHg (mean 10.23±1.88 mmHg). No predictor variable other than gender and central corneal thickness had a significant correlation with either corneal hysteresis or corneal resistance factor. Corneal hysteresis was positively associated with female sex and with central corneal thickness, and corneal resistance factor was positively associated with central corneal thickness. CONCLUSION: Despite the associations found, only a small fraction of the variance in biomechanical measurements could be explained by the descriptors that were evaluated, indicating the influence of other corneal aspects on the biomechanical characteristics.


Subject(s)
Humans , Male , Female , Cornea/physiology , Anterior Eye Segment/physiology , Tonometry, Ocular , Biomechanical Phenomena/physiology , Bayes Theorem , Cornea/anatomy & histology , Intraocular Pressure/physiology , Anterior Eye Segment/anatomy & histology
3.
Arq. bras. oftalmol ; 80(6): 364-368, Nov.-Dec. 2017. tab, graf
Article in English | LILACS | ID: biblio-888165

ABSTRACT

ABSTRACT Purpose: To assess changes in anatomic structures in the anterior eye segment in terms of axial lengths with accommodation via optical coherence tomography. Methods: In this observational study, 25 eyes of 25 healthy adults were examined using the Visante® omni optical coherence tomography system. Central corneal thickness, anterior chamber depth, central lens thickness, and anterior segment length were assessed. The evaluated parameters were obtained with accommodation using different stimulus vergences, namely 0.0, -1.0, -2.0, and -3.0 D. Variation of these parameters was compared among different levels of accommodation. Results: Central corneal thickness was not altered at any stimulus vergence during accommodation (p>0.05). Conversely, anterior chamber depth was significantly reduced (p<0.05), whereas central lens thickness was significantly increased (p<0.05). Anterior segment length also increased with accommodation (p<0.05), indicating backward movement of the posterior pole. Conclusions: There are significant variations in anterior segment lengths that occur with accommodation. Studying these changes will provide useful information regarding the accommodation mechanism that can improve our understanding of this process and facilitate clinical decision-making by practitioners.


RESUMO Objetivo: Avaliar as mudanças das estruturas anatômicas no segmento anterior do olho em termos de comprimentos axiais com acomodação por meio da tomografia de coerência óptica. Métodos: Neste estudo observacional, foram incluídos 25 olhos de vinte e cinco adultos saudáveis e medidos com o sistema Visante® omni tomografia de coerência óptica. A espessura corneana central, a profundidade da câmara anterior, a espessura central da lente e o comprimento do segmento anterior foram avaliados. Os parâmetros avaliados foram obtidos com acomodação usando diferentes vergências de estímulo: 0,0, -1,0, -2,0 e -3,0 D. A variação desses parâmetros foi comparada para os diferentes níveis de acomodação. Resultados: A espessura corneana central não foi alterada em nenhum estímulo durante a acomodação (p>0,05). A ACD mostrou uma redução significativa (p<0,05), enquanto a espessura central da lente foi significativamente aumentada (p<0,05). O comprimento do segmento anterior também aumentou com acomodação (p<0,05) indicando um movimento do polo posterior para trás. Conclusões: Há variações significativas nos comprimentos do segmento anterior que ocorrem com acomodação. Estudar essas mudanças fornece informações úteis sobre o mecanismo de acomodação para os profissionais, a fim de obter uma melhor compreensão desse processo e ajudá-los a tomar suas decisões clínicas.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Young Adult , Tomography, Optical Coherence , Accommodation, Ocular/physiology , Anterior Eye Segment/anatomy & histology , Anterior Eye Segment/diagnostic imaging
4.
Arq. bras. oftalmol ; 80(5): 285-289, Sept.-Oct. 2017. tab, graf
Article in English | LILACS | ID: biblio-888151

ABSTRACT

ABSTRACT Purpose: To determine the relationship between anterior segment and optic nerve head (ONH) parameters. Methods: Two hundred healthy subjects were enrolled in this study. The par­ticipants underwent measurement of anterior segment parameters with a Pentacam Scheimpflug system and imaging of the optic disc with confocal scanning laser ophthalmoscopy. Pearson's correlation coefficient was calculated to assess the associations between ONH and anterior segment parameters. Multivariate regression analyses controlling for age and disc area as confounding factors were also conducted. Results: There were significant negative relationships between optic disc area and corneal thickness (p=0.03, r=-0.217) and volume (p=0.017, r=-0.239). Corneal refractive power was significantly correlated with cup area, rim area, rim volume, and cup/disc ratio (p<0.05 for all). An increase of 1 diopter in anterior corneal refractive power corresponded to a decrease of 0.022 in cup/disc ratio. Rim volume was negatively correlated with anterior chamber depth and anterior chamber volume (p<0.05 for both). A 1-mm3 increase in anterior chamber depth corresponded to a 0.154-mm3 decrease in rim volume. Mean and maximum cup depth measurements were not associated with any of the anterior segment parameters. Conclusions: In nonglaucomatous eyes, the dimensions and shape of the ONH may be related to anterior segment morphology. Therefore, it may be helpful to take anterior segment parameters into consideration in evaluating the OHN.


RESUMO Objetivo: Determinar a relação entre os parâmetros do segmento anterior e da cabeça do nervo óptico (CNO). Métodos: Duzentos indivíduos saudáveis foram incluídos neste estudo. Os participantes foram submetidos à medição dos parâmetros do segmento anterior com o sistema Pentacam Scheimpflug e à obtenção de imagens de disco óptico com oftalmoscopia a laser de varredura confocal. O coeficiente de correlação de Pearson foi calculado para avaliar as associações entre CNO e os parâmetros do segmento anterior. Realizaram-se também análises de regressão multivariada que controlam a idade e a área do disco como factores de confusão. Resultados: Houve uma relação negativa estatisticamente significativa entre a espessura da córnea, o volume da córnea e a área do disco óptico (p=0,03, r=-0,217 e p=0,017, r=-0,239, respectivamente). As medições do poder de refração da córnea mostraram correlações significativas com a área da escavação, a área da rima, o volume da rima (RV) e a relação escavação/disco (C/D). (P<0,05 para todos). Um aumento de dioptria no poder de refração corneana anterior corresponde a uma diminuição de 0,022 em C/D. O RV mostrou correlação negativa com a profundidade da câmara anterior (PCA) e volume da câmara anterior. (P<0,05 para ambos). O aumento de 1 mm3 na PCA corresponde a uma diminuição de 0,154 mm3 no RV. As médias e as medidas máximas de profundidade de rima não mostraram associação com nenhum dos parâmetros do segmento anterior. Conclusões: Em olhos não glaucomatosos, as dimensões e forma da CNO podem estar relacionadas com a morfologia do segmento anterior. Portanto, pode ser útil levar em consideração os parâmetros do segmento anterior na avaliação da CNO.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Young Adult , Optic Disk/anatomy & histology , Anterior Eye Segment/anatomy & histology , Ophthalmoscopy/methods , Optic Disk/physiology , Organ Size , Reference Values , Refraction, Ocular/physiology , Glaucoma/etiology , Multivariate Analysis , Prospective Studies , Risk Factors , Age Factors , Statistics, Nonparametric , Microscopy, Confocal/methods , Corneal Pachymetry , Intraocular Pressure/physiology , Anterior Eye Segment/physiology
5.
Rev. bras. oftalmol ; 75(2): 160-165, Mar.-Apr. 2016. tab, graf
Article in Portuguese | LILACS | ID: lil-779966

ABSTRACT

RESUMO Este artigo apresenta uma revisão dos princípios e das aplicações clínicas do princípio de Scheimpflug na área da imagiologia do segmento anterior. Ao disponibilizar uma imagem tridimensional do segmento anterior, esta tecnologia permite a caraterização da elevação e curvatura das superfícies anterior e posterior da córnea, o mapeamento paquimétrico, o cálculo do poder refrativo total da córnea e a biometria do segmento anterior. Na subespecialidade de cirurgia refrativa, esta abordagem melhora a capacidade de identificação de casos com risco de desenvolver ectasia, bem como de planeamento e de avaliação dos resultados dos procedimentos cirúrgicos. Recentemente, esta tecnologia foi introduzida na avaliação biomecânica in vivo da córnea e na cirurgia de catarata assistida por laser de femtossegundo.


ABSTRACT This article presents a review of the principles and clinical applications of the Scheimpflug principle in the anterior segment imaging. By providing a three-dimensional image of the anterior segment, this technology provides elevation and curvature data of the anterior and posterior surfaces of the cornea, pachymetric mapping, the total refractive power of the cornea and the anterior segment biometry. For the refractive surgery sub-specialty, this approach improves the ability to identify cases at risk of ectasia, as well as the planning and evaluation of the results of surgical procedures. Recently, this technology was introduced in corneal biomechanical in vivo evaluations and in femtosecond laser-assisted cataract surgery.


Subject(s)
Humans , Ophthalmology/instrumentation , Biomechanical Phenomena , Photography/methods , Cornea/anatomy & histology , Anterior Eye Segment/anatomy & histology , Tonometry, Ocular , Algorithms , Image Processing, Computer-Assisted , Data Display , Photography/instrumentation , Photography/standards , Tomography/methods , ROC Curve , Biometry/instrumentation , Cornea/pathology , Cornea/diagnostic imaging , Corneal Topography/methods , Imaging, Three-Dimensional , Diagnostic Techniques, Ophthalmological , Anterior Eye Segment/pathology , Anterior Eye Segment/diagnostic imaging
6.
Pesqui. vet. bras ; 29(4): 286-290, Apr. 2009. ilus, tab
Article in Portuguese | LILACS | ID: lil-519575

ABSTRACT

Avaliou-se 31 cães saudáveis, sem raça definida, sendo 10 machos e 21 fêmeas, com 8 meses a 7 anos de idade e peso de1,5-28 kg. Inicialmente foram mensurados os diâmetros fronto-occiptal (DFO) e bizigomático (DBZ) do crânio com o auxílio de um paquímetro. A ultra-sonografia transpalpebral em modo-B foi realizada para mensurar as estruturas do bulbo ocular, conforme se segue: D1- espessura da córnea; D2- distância entre o ponto central da imagem da córnea e a da cápsula anterior do cristalino (câmara anterior); D3- distância entre o ponto central da imagem da córnea e a da cápsula posterior do cristalino; D4- espessura do cristalino, que corresponde a distância entre a imagem da cápsula anterior e a cápsula posterior do cristalino; D5- diâmetro do cristalino, distância entre as imagens dos pólos do cristalino; D6- área do cristalino; D7- câmara vítrea, distância entre a imagem da cápsula posterior do cristalino e a retina; D8- distância entre a cápsula anterior do cristalino e a retina; D9- distância entre a imagem da córnea e a retina. Com exceção da D4, houve efeito dos DFO e DBZ sobre as medidas das estruturas internas do BO. A análise de regressão linear entre as medidas das estruturas do bulbo ocular e os DFO e DBZ foram significativas para D1, D2, D3, D4, D5, D6, D7, D8 e D9.


In the experiment 31 healthy mongrel dogs, 8 months to 7 years of age, were used, 10 males and 21 females, weighing 1.5-28 kg. Initially, fronto-occipetal (FOD) and bizigomatic (BZD) diameters were measured using a caliper. The ophthalmologic transpalpebral B-mode ultrasonography (US) was performed to measure the ocular bulbi structures, as follows: The cornea thickness (D1), distance between cornea and anterior lens capsule (D2), distance between cornea and posterior lens capsule (D3), lens thickness (D4), lens diameter (D5), lens area (D6), distance between posterior lens capsule and retina (D7), distance between anterior lens capsule and retina (D8), and the distance between cornea and retina (D9). Except for D4, there were effect of FOD and BZD on the measures of the internal structures of BO. The Lineal Regression Analysis between the measures of the internal oculars structures and DFO and DBZ were significant for D1, D2, D3, D4, D5, D6, D7, D8 and D9.


Subject(s)
Animals , Biometry/methods , Skull/anatomy & histology , Dogs , Anterior Eye Segment/anatomy & histology , Ultrasonography
7.
RPG rev. pos-grad ; 15(1): 32-37, jan.-mar. 2008. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-529490

ABSTRACT

Foi realizado um estudo dos sinais anatômicos presentes em ambas as íris do globo ocular de 112 indivíduos, escolhidos aleatoriamente, por meio de imagens fotográficas digitais. Foram elaboradas tabelas de avaliação dos sinais: lacunas, anéis de tensão, radiis solaris, sulcos radiais, sulcos radiais, manchas, flocos de neve, nuvens e anel de gordura, verificando a freqüência com que os mesmos aparecem nas íris consideradas de cor escura (castanho, castanho claro e castanho escuro), de cor clara (azul, verde e cinza) e de cor média (hazel e âmbar). Os dados obtidos foram processados em análise estatística por meio do teste exato de Fisher e qui-quadrado, com nível de significância de 5%. Os resultados mostraram que: os sinais anatômicos são menos evidentes nas íris de cor escura, sendo que as lacunas e os anéis de tensão foram os mais observados e as nuvens não foram obsevadas; nas íris de cor clara, os sinais mais notados foram as manchas e os flocos de neve e o anel de gordura não foi notado; as íris de cor média foram as que apresentaram maior variedade de sinais, prevalecendo os anéis de tensão e as lacunas, e os menos freqüêntes foram as nuvens e o anel de gordura; o sinal anel de gordura foi observado apenas em indivíduos em idade superior a 50 anos. Por fim verificou-se também que a íris direita e esquerda do mesmo indivíduo são similares, mas não iguais, havendo pequenas alterações na quantidade do mesmo sinal presente em ambas.


Subject(s)
Eye, Artificial , Iris , Eye/anatomy & histology , Angioid Streaks , Color , Signs and Symptoms , Anterior Eye Segment/anatomy & histology
8.
Indian J Ophthalmol ; 2008 Jan-Feb; 56(1): 17-22
Article in English | IMSEAR | ID: sea-72266

ABSTRACT

PURPOSE: To compare the anterior segment parameters in photopic and scotopic conditions using anterior segment optical coherence tomography (AS OCT) in Indian eyes. MATERIALS AND METHODS: One hundred eyes of 100 normal subjects of both sexes, aged 19 to 76 years, underwent anterior segment evaluation by AS OCT (Visante OCT). Central corneal thickness (CCT), central anterior chamber depth (ACD), pupil diameter (PD) and the temporal and nasal peripheral irido-corneal angles were assessed in photopic and scotopic conditions. These anterior segment parameters were stratified for age, sex and refractive error. RESULTS: Mean values of the parameters measured in photopic and scotopic conditions respectively were as follows: ACD (mm) 2.88 +/- 0.32, 2.89 +/- 0.32 (P = 0.10); nasal angle (degrees) 28.80 +/- 5.91, 22.28 +/- 7.50 (P < 0.001); temporal angle (degrees) 29.95 +/- 6.74, 22.82 +/- 8.43 (P < 0.001); pupil diameter (mm) 4.08 +/- 0.91, 4.68 +/- 0.92 (P < 0.001); CCT (microm) 519 +/- 33.88, 519 +/- 33.88. CONCLUSIONS: There was no significant difference in the ACD in photopic and scotopic conditions. While the nasal and temporal angles showed a significant decrease, the pupil diameter showed a significant increase in scotopic conditions. Mean central ACD decreased with age and was shallower in females than in males. It was highest in myopes and lowest in hypermetropes. CCT was not influenced by photopic and scotopic conditions.


Subject(s)
Adult , Aged , Anterior Eye Segment/anatomy & histology , Female , Humans , Lighting , Male , Middle Aged , Refraction, Ocular , Tomography, Optical Coherence
9.
Arq. bras. oftalmol ; 70(2): 330-336, mar.-abr. 2007.
Article in Portuguese | LILACS | ID: lil-453177

ABSTRACT

OBJETIVO: Determinar a presença de simetria das medidas morfométricas do segmento anterior entre olhos adelfos normais. MÉTODOS: Foram examinados, pela biomicroscopia ultra-sônica (UBM), 178 olhos de 89 pacientes com exame oftalmológico normal. Em cada olho, além da profundidade da câmara anterior (PCA), foram realizadas onze outras medidas que caracterizam a morfometria do segmento anterior em 4 quadrantes distintos (superior, nasal, inferior e temporal). Determinou-se a presença da simetria e a intensidade da correlação das medidas entre olhos direitos e esquerdos, para cada uma das medidas morfométricas, nos meridianos pesquisados. RESULTADOS: Para a maioria das variáveis estudadas, não foram observadas diferenças estatisticamente significativas na morfometria do segmento anterior, entre olhos adelfos. Apenas duas variáveis, em dois meridianos distintos, apresentaram diferenças estatisticamente significativas, que foram inferiores a 0,025 mm, sendo consideradas clinicamente não-significativas, por se situarem no limite da precisão da UBM. A análise de Pearson demonstrou correlação estatisticamente significante entre as medidas obtidas entre os olhos, de intensidade, em geral, moderada para todas as variáveis, exceto para a variável PCA, cuja correlação foi considerada excelente. CONCLUSÃO: Em olhos adelfos com refração e biometria semelhantes, foi observada a presença de simetria nos parâmetros que caracterizam a morfometria do segmento anterior.


PURPOSE: To determine the presence of symmetry of anterior segment morphometric measurements between normal adelphic eyes. METHODS: One hundred and seventy-eight eyes of 89 subjects with normal ophthalmic examination were examined by ultrasound biomicroscopy (UBM). In each eye, the anterior chamber depth (ACD) as well as 11 other measurements that characterize anterior segment morphometry were measured in 4 different quadrants (superior, nasal, inferior and temporal). The presence of symmetry between right and left eye for each of these variables was then compared for each meridian. RESULTS: No significant statistical differences were observed concerning anterior segment morphometry between right and left eyes for most measured parameters. Only two variables, in two different meridians, presented statistical significant differences between right and left eyes. The difference, however, was inferior to 0.025 mm, which is beyond the precision of UBM and therefore was not considered to be clinically significant. Pearson correlation analysis demonstrated the presence of a statistical significant correlation, with a moderate intensity for the majority of the variables except ACD, whose correlation was excellent. CONCLUSION: This study demonstrated that symmetry of morphometric measurements between right and left eyes is expected to occur, provided these eyes have similar refractive errors and biometric measurements.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Anterior Chamber/anatomy & histology , Anterior Chamber , Anterior Eye Segment/anatomy & histology , Anterior Eye Segment , Retinal Detachment , Biometry , Intraocular Pressure/physiology , Microscopy, Acoustic , Models, Statistical , Prospective Studies , Refractive Errors , Vision Screening
10.
Arq. bras. oftalmol ; 69(6): 919-922, nov.-dez. 2006. tab
Article in English | LILACS | ID: lil-440433

ABSTRACT

PURPOSE: To determine if pars plana vitrectomy induces long-term changes in the anterior segment anatomy by means of ultrasound biomicroscopy. METHODS: A prospective case series study was undertaken of consecutive patients referred to a tertiary eye care centre for pars plana vitrectomy as the only procedure. Twenty eyes of 20 patients undergoing pars plana vitrectomy alone were studied by ultrasound biomicroscopy. Silicone oil or scleral buckle was not used in any of the included cases. The following morphometric parameters were compared before and after 3 months of surgery: anterior chamber depth, angle-opening distance at 500 æm from the scleral spur, trabecular-ciliary process distance, ciliary body thickness at 1, 2 and 3 millimeters from the scleral spur and measurement of the supraciliary space thickness, when fluid was detected. RESULTS: No statistically significant differences were found between the preoperative and the postoperative morphometric parameters. CONCLUSION: Uncomplicated pars plana vitrectomy does not induce any long-term change on anterior segment morphometry. Based on these findings, the normal long-term pattern to be expected after pars plana vitrectomy is the conservation of the preoperative morphometry.


OBJETIVOS: O objetivo do presente estudo foi determinar, por meio da biometria ultra-sônica (UBM), se a vitrectomia via "pars plana" pode induzir alterações permanentes na anatomia do segmento anterior. MÉTODOS: Foi realizado estudo prospectivo, analisando-se uma série consecutiva de pacientes, encaminhados para um centro de referência terciário para serem submetidos a vitrectomia via "pars plana" como único procedimento. Vinte olhos de 20 pacientes a serem submetidos a vitrectomia como único procedimento foram estudados pela biomicroscopia ultra-sônica. Oleo de silicone ou introflexão escleral não foram usados em nenhum dos casos incluídos. Os seguintes parâmetros morfométricos foram comparados antes e após 3 meses da cirurgia: profundidade da câmara anterior, abertura do ângulo a 500 æm do esporão escleral, distância trabéculo-processos ciliares, espessura do corpo ciliar a 1, 2 e 3 milímetros do esporão escleral e medida da espessura do espaço supraciliar, quando fluido foi detectado. RESULTADOS: Não foram encontradas diferenças estatisticamente significativas entre os períodos pré e pós-operatório para os parâmetros morfométricos estudados. CONCLUSÃO: A vitrectomia via "pars plana" não-complicada não induz alterações permanentes na morfometria do segmento anterior. Com base nestes achados, o padrão normal esperado após a vitrectomia via "pars plana" é a conservação da morfometria pré-operatória.


Subject(s)
Humans , Male , Female , Child , Adolescent , Adult , Middle Aged , Anterior Eye Segment/anatomy & histology , Microscopy, Acoustic/methods , Retinal Diseases/surgery , Vitrectomy/adverse effects , Anterior Eye Segment/pathology , Anterior Eye Segment , Postoperative Period , Preoperative Care , Prospective Studies , Vitrectomy/methods
11.
Rev. bras. oftalmol ; 59(11): 822-8, nov. 2000. ilus, tab
Article in Portuguese | LILACS | ID: lil-297225

ABSTRACT

Objetivo: Estudar, através da biomicroscopia ultra-sônica, olhos portadores de aniridia com ou sem glaucoma. Local: Serviço de Glaucoma do Hospital São Geraldo (Hosp. das Clínicas da UFMG). Material e Métodos: Nove pacientes portadores de aniridia (sete olhos com glaucoma e 11 olhos sem glaucoma) foram submetidos à biomicroscopia ultra-sônica. Foram feitas medidas comparativas de vários parâmetros do segmento anterior em ambos os grupos. Resultados: O seio camerular apresentou-se bloqueado por goniossinéquias em todos os olhos portadores de glaucoma e em oito dos 11 olhos sem glaucoma, o corpo ciliar apresentou menor espessura da esclera justalímbica em olhos anirídicos com ou sem glaucoma em relação a olhos normais. Discute-se a patogenia do glaucoma na aniridia. Conclusões: Não foram encontradas diferenças significativas entre as medidas das estruturas do segmento anterior dos olhos portadores de aniridia com ou sem glaucoma, à exceção de fechamento sinequial (DASC = ) em todos os olhos anirídicos com glaucoma.


Subject(s)
Humans , Male , Female , Child , Adolescent , Adult , Aniridia , Glaucoma/etiology , Glaucoma/physiopathology , Anterior Eye Segment/anatomy & histology
SELECTION OF CITATIONS
SEARCH DETAIL